Metal Roof Maintenance

Aerial view of a long white metal building with a dark metal roof

Get Another Decade Out Of It

Whatever you keep under a metal roof, a leak usually starts with a small part rather than a panel. In metal roof maintenance, the fasteners and closures therefore get nearly all of the attention, because the panels, on their own, seldom need work. What follows covers what to check, how often to check it, and which problems deserve a repair and which are merely cosmetic.

Call (252) 414-5105

Get a Free Quote
Quality Assurance

Inspect once a year

Walk the edge of the building first, and bring binoculars before you bring a ladder.

Diverse Product Range

Loose screws are normal

After 15 to 20 years, some fasteners backing out is expected wear, not a defect.

Diverse Product Range

Foam closures wear out

Inexpensive foam eventually stops sealing, and it can be replaced.

Diverse Product Range

Pipe boots fail first

They are the most common single source of leaks.

Diverse Product Range

Chalking is only cosmetic

The steel under a chalky coating is not affected.

Diverse Product Range

Replacement parts from us

We sell screws, closures and boots, and there is no minimum order.

Aerial view of a white metal building with a dark metal roof

Metal roof maintenance: the yearly check, step by step

Start on the ground and walk around the building with binoculars; do not climb anything yet. You are looking for screws that have backed out, and a raised head or a dark ring around one gives it away. Check the ridge line for foam closures that have compressed or gone missing. Study the pipe boots, because they wear out sooner than any other part of the roof. Make sure the valleys and gutters are clear, since debris stuck in them keeps the coating damp. Only after all that should you think about getting up there, and then only on a dry day, in proper footwear.

Aerial view of a metal building with a light blue roof and gravel drive

Backed-out screws: expected, and easy to fix

Panels expand and contract every day, so over 15 to 20 years some of the fasteners work loose. Any roof with exposed fasteners behaves this way. The repair is simple: tighten the loose screws, and replace any whose washer has perished, using a screw a little larger in diameter so the thread has new material to grip. Every screw left loose is an open hole that a heavy rain will find.

Tall gray metal building with roll-up doors

Cosmetic problems and the ones that matter

A chalky surface or a coating that has faded a little is only cosmetic; the steel beneath is untouched. Oil-canning, the faint waviness that shows in flat areas of a panel, is how the panel looks and not a fault. Four problems are worth acting on: rust where a panel was cut or at a fastener hole, closures at the ridge that have compressed, pipe boots that have perished, and any panel that has lifted at a lap.

Red commercial metal building with windows and entry doors

Knowing when to stop repairing

If a large share of the fasteners are failing and the coating has broken down in several places, the roof is at the end of its service life and you are only patching it. At that point a new roof laid over the existing panels often costs less than chasing leak after leak. We will say plainly which of those cases you are in, and we will not sell you a complete roof before you need one.

Very long white metal building with black wainscot

Metal roof maintenance before and after a storm

Anchoring and upkeep are what let a steel building ride out a storm, and the upkeep is light. Before hurricane season, make a lap of the building: snug up or replace any fastener that has loosened, sweep leaves and pine needles off the roof and away from the base, and test that each door latches. Wind gets in most often through a roll-up door that has been left partly open.

When a storm is forecast, carry anything loose away from the building, shut and latch each door, and park vehicles well clear of trees. Afterward, inspect the anchors, scan the roofline for any trim that has pulled up, and hose off salt and debris. Near the water, it pays to rinse the building after any storm whose wind came in off the water; ten minutes is all it takes.

Through the year the chores are few: wash the panels, pull mulch and vegetation back from the base rail, touch up any scratch before it can rust, and make sure water drains away from the pad.

Large gray metal building with glass overhead doors

Eastern North Carolina storms and what they mean for a roof

Eastern North Carolina takes tropical weather more often than nearly anywhere else on the East Coast. Floyd (1999), Isabel (2003), Irene (2011), Matthew (2016), Florence (2018) and Dorian (2019) all remain fresh in local memory. Most of them did their damage as water rather than wind, and the conclusion people here drew is that a building depends on its anchoring and the ground beneath it.

So our first questions are about your site, not about colors. Heading from I-95 to the coast raises the design wind speeds, flood zones run along each river and sound, and your county decides which certification an inspector expects. Give us the location and we will quote framing, anchors and drawings to suit it.

Common Questions

How frequently should I check my metal roof?

Once a year is a sensible habit, and it is worth looking again after any severe storm. You can do much of the checking from the ground with binoculars. Look for raised screw heads, gaps along the ridge and pipe boots that have perished, and only then decide whether a climb is needed.

What makes the screws on a metal roof back out?

Thermal cycling: the panels expand and contract each day, and after 15 to 20 years some of the fasteners work loose. That is expected on roofs with exposed fasteners. Tighten what is loose, and replace any screw with a perished washer, ideally with one a little larger.

Does a metal roof ever need resealing?

The panels do not. What wears out over the years is the sealant around penetrations, the pipe boots and the foam closures at the ridge and eave. These are consumables; the steel, as a rule, is not.

Can a leaking metal roof be repaired?

In most cases, yes. The source of a leak is usually a fastener, a closure or a pipe boot rather than a panel, and each of the three is easy to replace. The parts are available from us with no minimum order. Describe where the water shows up when you call (252) 414-5105, because that usually reveals which of the three is to blame.

When does it make more sense to replace a metal roof than to repair it?

Once many fasteners are failing and the coating has broken down in several spots, the roof is near the end of its life. A new roof over the existing panels is then often cheaper than chasing leaks one at a time.

Ask for a real number, back in 24 hours

If you are planning something new, give us the size, your county and what will go inside. The quote follows current steel pricing and carries no obligation, and we will say so if another size would suit you better.

Request a Quote Design It in 3D