Two decisions decide whether a metal roof valley stays quiet or leaks: how wide the flashing is, and how the panels are cut where they meet it. A valley is where two roof planes drain into a single channel, so it carries more water than any other part of the roof and is the riskiest detail on the building. Choose flashing wide enough for peak flow and cut the panels properly, and you can forget about it. Get either one wrong and it will make itself known.

Call (252) 414-5105

Get a Free Quote
Diverse Product Range

Where two planes meet

No other part of the roof carries as much water.

Diverse Product Range

Never skimp on width

Narrow flashing shows its weakness in the first hard storm.

Diverse Product Range

Turn the cut edge

A hemmed edge steers water into the channel instead of letting it creep underneath.

Diverse Product Range

Clear it every year

Debris can dam the channel and make a sound roof leak.

Customize

Cut to length, your color

Flashing cut to the length of the run leaves fewer joints.

Diverse Product Range

Find the real source first

Fasteners and pipe boots are the more common culprits.

Aerial view of a white metal building with a dark metal roof

Why a metal roof valley carries so much risk

Over most of a roof, rain flows down a single slope and leaves at the eave. A valley changes that. Two slopes feed it, and everything they shed is squeezed into one channel, where on a steep roof the water picks up real speed. If the flashing is too narrow, the panels are cut badly or the sealing is poor, the fault shows up straight away and shows up again with every shower. Once fasteners are ruled out, valleys account for most metal roof leaks.

Aerial view of a metal building with a light blue roof and gravel drive

How wide to make the flashing, and how to cut the panel

Think of the flashing as a channel that must handle the heaviest flow it will ever see. If it is too narrow, water in a downpour climbs over the edge and runs beneath the panels, and the money saved on a thin strip is lost to the first hard storm. The panels that meet it are trimmed at an angle, and the trimmed edge should be hemmed, or folded over, so that water is sent down into the channel and cannot creep sideways under the panel. Between them, those two details carry most of the load.

Tall gray metal building with roll-up doors

Leaves, needles and grit in the channel

Trees drop leaves and pine needles into valleys, and grit washes in as well. Left there, the debris holds back water; the water backs up under the panel edges, and a roof with no other faults starts to leak. For that reason valleys belong on the yearly maintenance list, and a roof under a canopy of trees deserves flashing with plenty of width.

Large tan commercial metal building with a tall roll-up door

What to do about a leaking valley

Do not assume the valley is guilty. Water travels before it drips, so a stain can sit far from the entry point, and fasteners and pipe boots are the more usual culprits. Once the valley is confirmed, look at four suspects: flashing that is too narrow, panels cut too near the channel, debris blocking the flow, and sealant that has given way at the upper end of the run. We cut valley flashing to length in your color, and we are happy to talk through the detail before you order.

Very long white metal building with black wainscot

Why a metal roof suits our humid climate

Metal suits the weather we have. Fastened the right way, panels resist uplift better than worn shingles, they drain a downpour quickly, and the black streaks of algae that spoil shingle roofs in this humid climate do not take hold on them. A pale color helps too, turning back a good deal of summer heat, which you feel inside a barn or shop that has no air conditioning.

How well a roof ages by the coast comes down to its details. The quality of the fasteners, the closures at the eave and ridge, and trim that blocks wind-driven rain count for more than gauge alone, and a valley is the trim detail that carries the most water. Wash salt off a couple of times each year, and after any named storm look over the fasteners that are exposed.

Condensation needs planning, too. On a damp spring or fall morning, warm moist air touches a cold panel and the underside starts to drip. Insulation or a vapor barrier beneath the panels, with ventilation at the ridge and eaves, stops it, and fitting it while the roof is going on is much cheaper than retrofitting.

Large gray metal building with glass overhead doors

Roof valleys and Eastern North Carolina storms

Eastern North Carolina gets hit by tropical weather more than nearly any other stretch of the East Coast, and the storms still fresh in people’s minds are Floyd, Isabel, Irene, Matthew, Florence and Dorian, from 1999, 2003, 2011, 2016, 2018 and 2019. A few were wind events, but most were water events, and a roof valley is where a roof handles the most water. What we took from them is that no building is better than its anchoring and the ground beneath it.

Because of that, our first questions are about your site, not about paint. Wind loads a building must be designed for rise as you head from I-95 toward the water. Flood zones trace every river and sound. The county where you build also decides which certification its inspector expects. Tell us where the structure will stand and we will price framing, anchors and drawings to suit that location.

Common Questions

Why is my metal roof leaking along the valley?

Usually the flashing is too narrow for the volume of water, the panel cut sits too close to the channel, debris is damming the flow, or the sealant at the top of the run has failed. Check that the valley really is the source first. Leaks often appear far from where the water gets in, and fasteners and pipe boots are the more common offenders.

What width of flashing does a metal roof valley need?

Enough that water at its fastest cannot ride up beneath the panel edges. If you are unsure, go wider, particularly on a steep pitch, over a long run, or anywhere trees will drop debris into the channel. Do not try to save money on width.

Is sealant needed in a metal roof valley?

Sealant is a supporting player. The valley should stay watertight because of its flashing width and panel cut, with sealant added as a backup at the terminations. A valley that depends on sealant alone will start to leak as the sealant ages.

Can ECOP supply valley flashing for my metal roof?

Yes. We cut valley flashing to length in the color of your panels, and there is no minimum order. Phone (252) 414-5105 with the length of the valley and the pitch of the roof, and we will recommend a width.

A quote for your roof in 24 hours

Send us the size of the job, the county and what the building is used for. We price from current steel costs, with no obligation, and we will point out a better size if there is one.